Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04314
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/14/2005 | FRAMING | Approved | ||
01/26/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO INSULATE 2) STUD AT DIVERTER VALVE IS BROKEN 3) REPLACE WIRE BELOW CEILING IN MASTER BATH |
|
01/21/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NEED DRAIN, WASTE, VENT TESTED 2) STUD OVERSPAN AT WASHER, BOX-GARAGE SIDE 3) SECURE MECHANICAL DUCT, CEILING MASTER BEDROOM 4) DIVERTER STUD NOTCHED TO DEEP, NEED LET IN BRACING/BLOCKING 5) MISSED SW3 P.T. LAUNDRY ROOM |