Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM04310

Parcel: 126030160


Addresses:

730 N BENTON AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/16/2005 FRAMING Approved IVRS - Inspection :*
08/02/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROPER HEADER AT ENTRY DOOR
2) FURR OUT HOBBY ROOM SOUTH WALL
3) PROVIDE CONTINOUS TIE IN HOBBY ROOM SOUTH WALL. BEARING WALL MUST BE 16" ON CENTER
4) BREARING WALL NEEDED AT EAST CRAFT ROOM
5) PROVIDE BEARING WALL WEST LAUNDRY ROOM WALL
6) CLIP EXTERIOR EAST FAMILY ROOM EVERY JOIST. NAIL EVERY HOLE
7) OVERSPANED HEADER FAMILY ROOM WINDOWS
07/14/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*