Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2004 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 10/12/2004 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PROVIDE STEEL FOR FOOTERS-SEE DETAIL #2 |
|
| 09/29/2004 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :*/ 1) PLAN CALLS FOR FTGS UNDER EACH POST, SIZE 16 X 16 X 12" DEEP, 12" BELOW NATURAL GRADE. I PROBED WITH A LONG SCREWDRIVER, FTG NOT PER PLAN 2) YOU NEED TO UNDER PIN AT EACH POST 3) LIGHT AT NORTH SIDE OF PORCH, YOU NEED A LIST FOR OUTDOORS FIXTURE. FIXTURE J-BOX WIRING NOT TO CODE 4) INSTALL A FIXTURE WITH A MOUNTING BOX OR CONDUIT TO J-BOX THEN ROMEX TO LIGHT WHERE IS THE GROUND WIRE? WHAT TYPE OFF ROMEX DID YOU USE IT'S PAINTED, MUST BE SUNLIGHT RESISTANT 5) OK TO PUT FANS BACK TOGETHER | |
| 09/28/2004 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ILLEGAL ELECTRIC SPLICE AT NORTH END OF PORCH, MUST BE IN APPROVED ELECTRIC BOX 2) OPEN-REMOVE FAN TO VERIFY WIRING 3) EXPOSE FOOTING ON ONE POST TO A DEPTH OF 12" AND 16" WIDE |