Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/24/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/22/2005 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Check #12 wire at kitchen possible nail, or cut Strap at dining room dbl top plate requires 16d nails Nail protect electric at kitchen Repair shear at laundry Seal all penetrations from 1st to 2nd floor Stopped inspection |
|
| 02/17/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DECK NOT PER PLAN 2) REPAIR SHEAR AT LAUNDRY 3) DBL TOP PLATE NOT CONTINOUS UNDEE GLB 4) FIREBLOCKS MISSING AT KITCHEN 5) COMPLY WITH SECTION R602.6, R602.6.1 AND R602.8 6) NEXT FAILURE WILL RESULT IN A REFEE |
|
| 02/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPAIR SHEAR AT LAUNDRY AT ELECTRIC BOXES AND PLUMBING 2) FIRE BLOCK LANDING AT KITCHEN 3) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR 4) PROVIDE STUD SHOES FOR 2 X 6 STUD BEARING WALL AT HALL BATH AND 16 GAUGE STRAP WITH 16D NAILS AT DBL TOP PLATE 5) LATH NOT COMPLETE AT ENTRY 6) STRAP DBL TOP PLATE AT LAUNDRY WITH 16 GAUGE STRAP 7) FIRE BLOCKS MISSING AT BALLOON WALL 8) STOPPED INSPECTION |