Permit: T04CM04266

Parcel: 110035150

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T04CM04266

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/21/2005 BUILDING - FINAL Approved IVRS - Inspection :*
03/17/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LIGHT FIXTURE AT BEDROOM CLOSET BY GARAGE NOT 12" CLEARANCE FROM STACKABLE COMBUSTIBLES
2) PLUG KNOCKOUT BOTTOM SERVICE PANEL
3) LABEL ALL CIRCUITS MAIN SERVICE PANEL
4) NO FUSES AT CONDENSOR DISCONNECT
5) CAP EXTERIOR CLEANOUT BY CONDENSOR
6) PROVIDE GAS BOND
7) EXPOSED WIRING EXTERIOR NORTH WALL 3 COVER PLATES 8) CLEAR ALL ATTIC VENTS NEEDED AT OVERHANGS
9) EXPOSED BOXES IN ATTIC/BOXES NOT MADE UP