Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/23/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* CONTINUATION OF 4" BUILDING SEWER TO EXISTING WATER TEST OK 1. PROVIDE TRACER WIRE WASTE & VENT THRU ROOF WATER TEST OK |
|
| 10/12/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* ROUGH SOIL TOILET RMS THROUGH 2 WAY CO OK TO COVER CREECH'S PLUMBING CONTRACTOR |
|
| 10/11/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* ROUGH PLUMBING IN NEW RESTROOM LOCATION INSIDE BUILDING IS OK EXCEPT FOR FLOOR CLEANOUT. USE BRASS BODY FRANK PATTERN CLEANOUT FITTING OR INSTALL IN WALL AS SPECIFIED. TRACER WIRE REQUIRED OUTSIDE. 2" LAV WASTE OUTSIDE AND 4" SEWER AT 2-WAY CLEANOUT IS NOT PROPERLY SLOPED. ALSO VENTING NOT PER PLAN. |
|
| 05/16/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* - WATER TEST NEW FLOOR SINK & HAND SINKS IN EXISTING KITCHEN THRU ROOF & TO EXISTING VENT CONNECTION OK - WATER PIPING SAME OK 1. PENDING SECURING PEX AT 32" INTERVALS ABOVE CEILING. |
|
| 02/14/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) REVISED PLAN DATED 2/9/06 FROM PAUL ERIC ? ON SITE WILL NEED CITY APPROVAL. THIS PLAN SHALL ACT AS RED LINE ON SITE. 2) WATER TEST WASTE AND VENT THRU ROOF BAR AREA OK 3) WATER DISTRIBUTION IN WALL BAR AREA AIR TEST OK 4) NEED TO SEE CONTINUATION OF HOT AND COLD SUPPLY TO BAR AREA |
|
| 08/22/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WATER TEST SOIL UNDERGROUND EXTERIOR OF BUILDING OK |
|
| 08/09/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) NOTE: THIS INSPECTION IS FOR GREASE WASTE LINE ONLY 3) OK TO BACK FILL TRENCH |
|
| 08/08/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY FOR INSPECTION |