Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM04233
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/23/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) FROM LAST INSPECTION A/C LINE SET, FHA STRAP BOTH PLATES LIVING ROOM DBL TOP PLATE 2) INSTALL FIRE STOPS AT H20 HTR FLUE AT FLOOR, CEILING LINES |
|
12/21/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) H20 LINE PEX AT H20 HTR FLUE NEED 6" CLEARANCE 2) H20 HTR FLUE TO BE AT MAXIMUM 60 DEGREE AT OFF SET, INSTALL FIRE STOPS AT FLOOR/CEILING MAINTAIN 1' CLEARANCE TO COMBUSTIBLE 3) PLATE FHA BOTH PLATES, LINE SET 1ST FLOOR TOP PLATE 4) BANG PLATE PEX LINE IN POWDER ROOM |
|
12/20/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
12/17/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |