Permit: T04CM04230

Parcel: 141015060

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM04230

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/16/2005 FRAMING Approved IVRS - Inspection :*
02/14/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STUCCO LATH NOT COMPLETE ABOVE 1ST FLOOR
2) FIREBLOCK FLOOR AND CEILING PENETRATIONS AT FURNACE/WATER HEATER "B" VENT PENETRATION
3) OVER SPAN/STUD CUT KITCHEN SHEARWALL ADD STUD SOUTH OF RANGE HOOD AND NAIL ADDED STUDS TO SHEAR OSB
02/10/2005 FRAMING Partial Approval IVRS - Inspection :*
1) ADD TWO STUDS, ONE AT LAUNDRY AND ONE AT KITCHEN OVEN VENT
2) BLOCK UNDER HOLE CUT FOR FURNACE FLU 2ND FLOOR ROOF
02/07/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) SECURE AND BLOCK DUCTS GARAGE MOVE WIRE AWAY FROM FLU H20 HTR, CHECK HT. OF H20 HTR'S FLU
2) CUT STUD IN LAUNDRY, EXHAUST DUCT BROKEN SAME ROOM
3) CUT STUD KITCHEN, CHECK PLATE BOLTS KITCHEN/GARAGE SHEAR
4) BLOCK ALL MECH DUCTS
5) FINISH LATH
6) PEX LEAK IN WEST BATH, CHECK ALL JOINTS
7) BACKING NORTH TUB
8) POWER FOR N/W A/C
9) OUTLET WEST BATH NOT SECURE
10) DID NOT CHECK SHEARWALLS ON 2ND FLOOR
11) THIS HOUSE NEEDS TO BE CHECKED OVER TOO MANY ITEMS