Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM04230
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/19/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
01/14/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) SEE LAST INSPECTION |
|
01/13/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED RETRO FIT H.D. AT EACH SIDE OF LARGE WINDOW REAR WALL, INSIDE OF WINDOW 2) FINISH ALL EXTERIOR SHEATHING |
|
01/11/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CARPENTERS STILL WORKING |
|
01/10/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) MISSED DIAPHRAMS REAR SHEAR P.A.'S 2 TOTAL 2) FINISH NAILING EXTERIOR SHEAR 3) BLOCK OSB TURNED WRONG WAY ROOF WEST 4) FINISH ALL P.A.'S 5) USE 16D IN LONG SPAN HANGERS LIVING ROOM |