Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* 1) HOLE IN DRYER EXHAUST |
|
| 03/07/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST ADDRESS 2) PAINT ALL ROOF VENTS 3) PROVIDE ACCESS TO ROOF 4) UNABLE TO ENTER TO INSPECT ALL EXTERIOR DOORS LOCKED |
|
| 02/28/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) CUT OFF CLEANOUTS TO GRADE 2) INSTALL 90 DEGREE ELBOW ON T & P AND CONDENSATE 3) NEED ANTI-SYPHON ON HOSE BIB 4) 3" VENT MINIMUM 12" ABOVE ROOF 5) SECURE FLEX AT A/C ROOF UNIT 6) MAXIMUM FUSE SIZE IS 60/60, CLEAR AMPACITY IS 51-54 CIRCUIT BREAKER IS 50/50 INSTALLED, VERIFY WIRE SIZE IS #6 CU. THEN OK TO INSTALL 60/60 BREAKER 7) CHECK ALL RECEPTACLES SOME ARE LOOSE |