Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/18/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/17/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REMOVE ANY WIRES FROM BUSS BARS 2) INSTALL 20 AMP GFI AND BREAKER 3) INSTALL REDHEADS WHERE MARKED AT BASE PLATE JOINTS 4) INSTALL BLOCK AT CENTER TUB TOP PLATE |
|
| 03/11/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL STUDS NEEDED AT ALL HOLDOWNS 16D EVERY HOLE 2) INSULATE ALL CHANNELS 3) BLOCK MISSING CENTER TUB TOP PLATES (FIREBLOCK) 4) RED HEAD AT FRONT DOOR PLATE |
|
| 03/09/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO TEST DWV OR POTABLE H20 2) EXHAUST FOR KITCHEN ? 3) MECH NOT PER PLAN 4) COMPLETE ALL TRADES AND RECALL 5) STOPPED INSPECTION |