Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04197
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/21/2005 | FRAMING | Approved | IVRS - Inspection :* | |
04/20/2005 | FRAMING | Cancelled | CANCELLED PER SUPER | |
04/19/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FURR OUT B-VENT 2) NEED 1" CLEARANCE TO B-VENT 3) OK TO INSULATE 4) REWIRE RECEPTACLE 2ND FLOOR AT B-VENT |
|
04/15/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ADD BLOCKING BETWEEN FLOORS WEST SIDE AT GIRDER TRUSSES 2) REPLACE STUD KITCHEN WALL 3) ADD STUD EACH SIDE OF REGISTER FROM PANTRY TO 4R 4) ADD STUD KITCHEN BY VENT 5) REWIRE 2 RECEPS IN KITCHEN 6) PROPERLY SUPPORT 2ND FLOOR ABS 7) CHANGE H20 HEATER B-VENT 8) CAULK STOVE HOOD 9) CHANGE WINDOW ON STAIRS TO TEMPERED 10) USE HU 3.25 HANGER AT GLU LAMS AT STAIRS |