Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/26/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 04/25/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSULATION CERTIFICATE STATES 8" CELLULOSE IS R-30-PROVIDE PROOF 2) INSULATION CERTIFICATE STATES 8" CELLULOSE MEASURES BETWEEN 6" + 7" 3) 18 APRIL CERT WAS VOIDED APRIL 22, YOU MUST PROVIDE A NEW CERTIFICATE DATED AFTER APRIL 24, 2005 4) NO LIGHT IN ATTIC |
|
| 04/22/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MUCH OF ATTIC HAS LESS THAN 8" OF CELLULOSE INSULATION. R-30=8.56" 2) FURNACE DRAIN PAN FULL OF INSULATION 3) FURNACE B-VENT HAS REVERSE PITCH AND IS LESS THAN 1" TO COMBUSTIBLES 4) INSULATION CERTIFICATE VOID. NEW CERTIFICATE REQUIRED |