Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/03/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/29/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)NAIL PROTECT WIRES WEST BEDROOM WEST WALL TOP PLATE. 2)VAPOR BARRIER MISSING AT WATER SERVICE |
|
| 12/27/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE BLOCK GARAGE BY ENTRY 2) RED HEAD ANCHOR BOLTS LOOSE 3) FIRE BLOCK LAUNDRY 4) LATH PENETRATIONS NOT CAULKED 5) NAIL PROTECT WIRES WITHIN 1 1/4" OF PLATE SURFACE WEST BEDROOM 6) FIRE BLOCK MISSING AT KITCHEN (2) 7) LATH NOT STAPLED UNDER PORCH LEDGER 8) PROVIDE BLOCK LATH NAIL PER 10/A8A 9) SHIM CRIPPLES ABOVE WINDOWS 10) VAPOR BARRIER MISSING AT WATER SERVICE 11) FIRE BLOCK SOUTH SIDE OF ENTRY |
|
| 10/29/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |