Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04151
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/29/2005 | FRAMING | Approved | IVRS - Inspection :* | |
03/28/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) BOLT H/D BATHROOM 2) NAIL OFF FS TO B-10 3) OK TO INSULATE 4) COMPLETE NORTH GABLE; STAPLE 2ND FLOOR WEST SIDE |
|
03/25/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED BOLTS IN HOLDOWNS 2) NAIL OFF F5 AND B10 16D AT 4" ON CENTER 3) FIREBLOCK TUB 4) BLOCK REGISTER MASTER CLOSET AND TOILET 5) LOWER S/D TO 6-12" FROM CEILING 6) ADD S/D DOWNSTAIRS HALL 7) NAIL STOP 8) CHECK ATTACHMENT OF ELECTRIC BOXES THROUGHOUT 9) PENDING MESH 10) 1" CLEARANCE TO W/H B-VENT |