Permit: T04CM04135

Parcel: 115154140


Addresses:

831 W CALLE SUR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
09/30/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
09/27/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SECURE GAS LINE AT H20 HEATER 2) INSTALL TYPE B VENT HEATER 3) INSTALL NEW PRESSURE/TEMP RELIEF VALVE AND LINE TO EXTERIOR OF CABINET 4) MUST HAVE SHUT OFF VALVE BEFORE UNION ON ROOF 5) MUST SUPPORT GAS PIPING ON ROOF MAXIMUM 6' SPACING 6) COMPLETE ALL ABOVE 7) RETEST AND RECALL FOR 03050 AGAIN
09/24/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NO PRESSURE TEST ON GAS LINE. MUST HAVE MINIMUM OF 10 PSI PRESSURE ON LINE AT TIME OF TEST