Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04126
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/04/2005 | FRAMING | Approved | IVRS - Inspection :* | |
12/28/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAILS MISSING AT HOLDOWN #3 BELOW ADD NAILS TO ADDED STUD EQUAL TO HOLDOWN NAILS |
|
12/20/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSULATED PRIOR TO RE-INSPECTION |
|
12/13/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE FOR SHEAR WALL NAILING BEHIND KITCHEN SUPPORT 2) FIRE BLOCK KITCHEN SOFFIT 3) PROVIDE HOLDOWN NORTH END OF KITCEHN SHEAR WALL 4) KITCHEN SHEARWALL MUST BE 13'-6" HOLDOWN TO HOLDOWN 5) OVERSPAN STUD MISSING GARAGE 6) MAXIMUM SIZE OF LAV DIRTY ARM 1 1/2" OVERSIZED 7) LEAK UNDER MASTER TUB 8) TRUSS H2.5 CLIPS MISSING AT PATIO DOOR 9) CONDENSATE OUT OF WALL 10) FIREBLOCK MISSING AT ENTRY |