Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/17/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/16/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIREBLOCK MECH CHASES 2) H.D. NOT NAILED 3) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT B-VENTS 4) SECURE GAS LINE IN ATTIC |
|
| 02/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/14/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE BLOCK MECH CHASES 2) ROOFING MATERIAL TOUCHING B-VENTS, 1" CLEARANCE REQUIRED 3) NO ATTIC ACCESS 4) PROVIDE 30" OF WORK SPACE IN FRONT OF UNIT 5) SEE NOTES 3, 6 AND 7 |
|
| 02/11/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED ON SITE BY JAMES (K.B. HOMES) |
|
| 02/09/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LEVEL NOT NAILED 4" ON CENTER 2) PLUMBERS TAPE NOT ALLOWED TO SUPPORT ABS 3) 3" VENT/DRAIN OUT OF WALL AT LAUNDRY 4) DRAIN LEAKING ABOVE AT LAUNDRY 5) BLOCKING PANELS MISSING AT GARAGE 6) FIREBLOCKS MISSING AT STAIRS 7) INTERIOR HOLDOWNS MISSING 8) STOPPED INSPECTION |