Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/15/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 04/13/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Bedrooms not insulated Insulation certificate states house insulated. Certificate voided-new certificate needed Water heater vent requires 3 screws Provide 22" x 48" low roof attic access |
|
| 04/11/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) T & P LINE MUST EXHAUST DOWN 2) SEWER PLUGGED 3) SECURE W/H "B" VENT 3 SCREWS 4) INSULATION CERTIFICATES STATES ATTIC INSULATED WITH FIBERGLASS BATT. BLOWN IN CELLULOSE USED COMPLY WITH 2000 IRC SECTION N1101.3 5) FRONT TWO BEDROOMS ATTIC SOUND HOLLOW. PROVIDE PROOF THAT INSULATED 6) PROVIDE ATTIC VENTILATION BY PROVIDING 2 X 4 OVERFRAME ACCESS |