Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/28/2005 | ROOF NAILING | Approved | IVRS - Inspection :* AP |
|
| 01/26/2005 | ROOF NAILING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* |
|
| 01/19/2005 | ROOF NAILING | Partial Approval | IVRS - Inspection :* 1) OK TO LOAD (ROOF) |
|
| 01/11/2005 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* 1) LEAVE COPY OF TRUSS DRAWINGS ON SITE 2) SHIM ALL 3 PT BEARING TRUSSES (FULL BEARING) 3) USE 16D COMMON NAILS IN TRUSS TO GIRDER CONNECTION HUS26 HANGERS, 10D TECO'S GOOP FOR 54 PERCENT LEAD CARRIED 4) SHEAR PANELS BUILT BETWEEN TRUSSES GARAGE SHEAR TRANSFER 5) CONCRETE REPAIR, NEED ENGINEERED DETAIL STAMPED BY ENGINEER OF RECORD 6) MISSING TWO SD DETAIL PAGES IN THIS PLAN SET |
|
| 12/16/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SOUTH WEST CORNER OF SLAB, CABLE HAS FAILED PROVIDE ENGINEERING REPAIR AND APPROVED BY CITY OF TUCSON 2) DO NOT LOAD ROOF UNTIL SLAB REPAIR IS DONE 3) CHECK ALL OVERFRAMING AND EDGE NAILING |
|
| 12/13/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO SHEARWALL PLANS 2) NO TRUSS DRAWINGS 3) NO LADDER 4) 2ND REJECTION REFEE DUE |
|
| 12/10/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE ACCESS TO ROOF |