Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/03/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) INTERIOR SHEAR CONNECTION Z/OB COMPLY WITH 2) BLOCK 3 SIDES INTAKE ABOVE REAR SLIDING DOOR 3) OK TO INSULATE |
|
| 12/01/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) LOOSE BOTTOM PLATE FRONT DOOR 2) FINISH CONDENSATE LINES TO ATTIC UNIT 3) BACKING MASTER TUB, LOOSE PLATE AT MASTER CLOSET 4) LOOSE STUD HALL TO FRONT BEDROOM 5) ROMEX HANGING FROM CEILING, FRONT HALL 6) WHAT BRAND NAME IS OFF SET CLOSET FLANGE ? 7) OVERSPAN STUD (EAST/MIDDLE) BEDROOM, MARKED ON FLOOR 8) INTERIOR SHEAR, CONNECTIONS TO TRUSSES SOME NOT NAILED, SOME HAVE TO LARGE A GAP 9) FINIS STUCCO LATH |