Permit: T04CM03991

Parcel: 14117005B


Addresses:

7431 S HOUGHTON RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T04CM03991

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
03/04/2005 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
02/10/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*TAG OUT MAIN BLD OK
02/09/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* LEDGER@FRONT/TOP OUT REAR. 1) FINISH KNOCKING IN BOLTS & STRAPS. OK TO GROUT OFTEN SQ. INSP. CONFIRMS
02/04/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* TO BOND ?? & LE?/REAR
02/03/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*12" REAR LINTEL FRONT
02/02/2005 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*NOT READY
02/01/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* P 8'. 1) YOU HAVE NOT MAINTAINED VERTICALS AT EACH FACE WHERE 2 VERTICALS ARE IN SINGLE CELL. PROVIDE INFORMATION FROM ENGINEER TO SEE IF BUNDLED BARS WILL WORK. REF 04/S0.2 2) YOU ARE REQUIRED TO MECHANICALLY CONSOLIDATE GROUT ( RE GSN) INMEDIATLY AFTER GROUTING. 3) NOTE 1 ABOVE OK PER ENGINEER ART CONTRELL-BUNDLED BARS AT JAMBS AND CONTROL JOINTS OK 10:35AM 3181777
01/31/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* PARTIAL 4' OK