Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T04CM03991
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/04/2005 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
02/10/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*TAG OUT MAIN BLD OK | |
02/09/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LEDGER@FRONT/TOP OUT REAR. 1) FINISH KNOCKING IN BOLTS & STRAPS. OK TO GROUT OFTEN SQ. INSP. CONFIRMS | |
02/04/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TO BOND ?? & LE?/REAR | |
02/03/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*12" REAR LINTEL FRONT | |
02/02/2005 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :*NOT READY | |
02/01/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* P 8'. 1) YOU HAVE NOT MAINTAINED VERTICALS AT EACH FACE WHERE 2 VERTICALS ARE IN SINGLE CELL. PROVIDE INFORMATION FROM ENGINEER TO SEE IF BUNDLED BARS WILL WORK. REF 04/S0.2 2) YOU ARE REQUIRED TO MECHANICALLY CONSOLIDATE GROUT ( RE GSN) INMEDIATLY AFTER GROUTING. 3) NOTE 1 ABOVE OK PER ENGINEER ART CONTRELL-BUNDLED BARS AT JAMBS AND CONTROL JOINTS OK 10:35AM 3181777 | |
01/31/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PARTIAL 4' OK |