Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T04CM03981
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/21/2005 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
01/14/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)IMPROPER CONDENSATE TERMINATION. DON'T DUMP ON ROOF. RUN 3/8" COPPER, BELOW CEIL. UP AND ACROSS ROOF. 2)IMPROPERLY FUSED 3)CONTROL WIRING EXPOSED TO SUN, CORRECT/RECALL |
|
12/30/2004 | MECHANICAL - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* |
|
12/29/2004 | MECHANICAL - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920*/1)SPACE NUMBERS 101, INCORRECT. SHOULD BE #100. 2)PHONE NUMBER PROVIDED BY BUSINESS OCCUPANT, INCORRECT, FOR A/C CONTRACTOR, 602-498-9043 3)SPLIT SYSTEM HEAT PUMP, SUSPENDED WALL HUNG AIR HANDLER W/REMOTE CONDENSER. NEED ROOF ACCESS. WANT TO SEE COMPLETED ELECTRICAL, FUSING, CONDENSATE TERMINATION, ETC. |