Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/04/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/01/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEARWALL TO EXTEND TO HOLDOWN NORTH SIDE
2) NO ROOF ACCESS
3) 2 BOLTS REQUIRED PER PLATE AT FRONT ENTRY COLUMN
4) H2.5 MISSING AT MID BEAM TO DBL PLATE AT ENTRY