Inspection History Details
Permit: T04CM03943
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/10/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/02/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 5 + ROWS OF ROOF NAILING MISSED ON UPPER-SOUTH HALF-CHECK ALL 2) ROWS MISSED ON ENTRY ROOF 3) STRAP TOP PLATES (1 PER PLATE) ON NORTH AND EAST WALLS WHERE OVERLAP IS INSUFFICIENT 4) NAIL SOUTH 2ND FLOOR SHEAR WHERE MISSED AND WHERE SHOT TOO DEEP 5) NAIL OFF LET-IN BRACING AT BOTTOM PLATES AND ADD BRACING TO WEST WALL 6) NAIL OFF NORTH LOWER GABLE TRUSS TO TOP PLATE |
|
| 10/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* |