Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM03943
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/10/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/02/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 5 + ROWS OF ROOF NAILING MISSED ON UPPER-SOUTH HALF-CHECK ALL 2) ROWS MISSED ON ENTRY ROOF 3) STRAP TOP PLATES (1 PER PLATE) ON NORTH AND EAST WALLS WHERE OVERLAP IS INSUFFICIENT 4) NAIL SOUTH 2ND FLOOR SHEAR WHERE MISSED AND WHERE SHOT TOO DEEP 5) NAIL OFF LET-IN BRACING AT BOTTOM PLATES AND ADD BRACING TO WEST WALL 6) NAIL OFF NORTH LOWER GABLE TRUSS TO TOP PLATE |
|
| 10/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* |