Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :*APPROVED. | |
| 12/21/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT CONDENSOR COPPER LINES 2) CLIPS MISSING NAILS 3) NAIL PROTECT ELECTRICAL FROM OUTSIDE ABOVE MAIN PANEL 4) OVERSPAN AT GARAGE WALL ( ENTRY AREA ) 5) PROVIDE 1/8" GAP ON ROOF SHEATHING 6) CHECK PATIO AND ROOF FOR NAILING |
|
| 12/20/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PORCH RAFTERS ARE TO BEAR ON DBL TOP PLATE (NOT LEDGERED) 2) KING STUDS AND ? STUDS NOT PER PLAN 3) NO ACCESS TO ROOF 4) ITEMS NOT CORRECTED 5) STOPPED INSPECTION |
|
| 12/09/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio 1) LAUNDRY ROOM WINDOW STRUD & HEADER ? 2) BRACE AT ENTRY TO ? 3) REPLACE BRACE AT RIGHT SIDE OF KITCHEN WINDOW. 4) KING STUD MISSING EACH SIDE OF S.G.D OPENING. 5) NO ACCESS TO ROOF 6) SEE LAST INSPECTION 7) STOPPED INSP |
|
| 12/07/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPLACE KING STUD AT KITCHEN WINDOW 2) WIND BRACE NORTH EAST BY KITCHEN WINDOW TO SHORT 3) PATIO POST CAPS MISSING 4) BLOCKS MISSING AT BACK PATIO LATH BACKING 5) GABLE NOT TOE NAILED 12" ON CENTER 6) STOPPED INSPECTION |
|
| 12/06/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) TO WET ON ROOF AND GROUND TO INSPECT 2) PLEASE RECALL INSPECTIONS |