Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/02/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/21/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) FLEX GAS CONNECTOR CANNOT PENETRATE MECHANICAL FIRE PLACE CABINET 2) FIRE BLOCK MISSING KITCHEN BY GAS LINE 3) NO DWV WATER TEST ON PLUMBING 4) ALL WIRES MUST TERMINATE IN APPROVED ELECTRIC BOXES KITCHEN 5) NAIL PROTECT PLUMBING AND ELECTRIC WITHIN 1 1/4" OF STUD WALL SURFACE 6) PEX PLUMBING NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS MASTER BATH AND THROUGHOUT 7) SANITARY "T" FITTING CANNOT BE USED AS DRAIN FITTINGS IN MASTER BATH 8) MAKE UP ALL GROUND WIRES IN BOXES AND CONNECT WITH MECHANICAL FASTENERS 9) PROVIDE WATER HEATER VENT AND COMBUSTION AIR AND T & P FOR GARAGE WATER HEATER 10) PROVIDE SOFFIT FOR PLUMBING AND ELECTRIC OUT OF WALL 11) STAIRS HAVE OPENINGS LARGER THAN 4" 12) INSULATE DUCT WYES 13) GROUND ALL METAL ELECTRIC BOXES 14) W/H T & P LINE MUST EXHAUST OUTSIDE 15) DRAFT STOP MECHANICAL PLATFORM 16) BOND GAS LINE |
|
| 01/10/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE STUCCO MESH BEFORE INTERMEDIATE INSPECTIONS |
|
| 12/06/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |