Permit: T04CM03915

Parcel: 138133650


Addresses:

5776 S STINGRAY AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/09/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/03/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) GARAGE DOOR KIGN STUDS NOT CLIPPED
2) GLU LAM BEAM POSTS NOT CLIPPED
3) GARAGE STUDS NOT CLIPPED
4) OSB ON 2/SD2 TO SHORT MUST OVER ? TOP PLATE BY 7/8" AND BE NAILED TO TOP PLATE. NOT TO BOTTOM PLATE OF TRUSS
5) 1/SD2 NOT COMPLIED WITH
6) 2ND FLOOR TRIPPLE GIRDER REQUIRES TRIPPLE POST TO GROUND
7) OSB PANELS TOO TIGHT. REQUIRES 1/8" GAP ENDS AND EDGES