Permit: T04CM03892

Parcel: 103191010


Addresses:

2543 W TEOCALLI CT

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/27/2004 FRAMING Approved IVRS - Inspection :*
12/23/2004 FRAMING Partial Approval IVRS - Inspection :*
1) #1 ITEM FROM 12/21/04 INSPECTION GETTING FIXED
2) OK TO INSULATE
12/21/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE WALL SHEARWALL REMOVE OSB AND CARRY CONTINOUS FROM BOTTOM PLATE TO UNDERSIDE OF ROOF SHEATHING
2) METAL STRAPS DON'T SUFFICE
3) INSTALL ELECTRIC WIRES INTO ALL BOXES AND GROUND METAL BOXES
12/13/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL ALL STUCCO STAPLES THROUGH PAPWER AND RENAIL ALL STUCCO STAPLES MISSING STUDS
2) NEED APPROVED TRUSS DRAWINGS
3) GARAGE SHEARWALL TO BE CONTINOUS HORIZONTAL SPLINT CANNOT OCCUR AT SPLIT OF TOP PLATES
4) STRAP NON CONTINOUS TOP PLATE BOTH EXTERIOR WALL AND GARAGE
5) INSTALL ELECTRIC WIRES ALL BOXES AND GROUND ALL METAL BOXES
6) STOPPED INSPECTION