Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/01/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DATES ON ENGINEER SEAL FOR REPAIR ARE PRIOR TO START OF CONSTRUCTION ON HOUSE. ENGINEERING DOCUMENTS WILL BE REVIEWED BY STEVE LONG |
|
| 03/22/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/02/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 02/28/2005 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Nothing done from last inspection |
|
| 02/23/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT ELECTRIC AT LIVING ROOM PONY WALL. 2) LSL IN GARAGE NOT NAILED 4" O.C. 3) APPROVED STAMPED DATE BY C.O.T DOES NOT MATCH LOT 95 CONSTRUCTION DATES, SOMEONE JUST WROTE IN THE ADDRESS REPLACING LOT 32 |
|
| 02/22/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS FROM 2/17/05 NOT COMPLIED WITH #2 2) WATER LEAK ABOVE WATER HEATER 3) ELECTRIC WIRE OUT OF WALL CAVITY AT LIVING ROOM PONY WALL |
|
| 02/17/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PEX NOT ALLOWED WITHIN 6" OF "B" VENT W/H 2) SEAL FLOOR PENETRATIONS AT TUB 3) DWV WATER LEAK AT LAUNDRY 4) FHA STRAPS WITH 12-16D NAILS REQUIRED AT LAUNDRY DBL TOP PLATES 5) A/C COPPER OUTSIDE OF WALL CAVITY 6) 2ND FLOOR EAST LAV HORIZONTAL RUN REQUIRES 1/4" PER FOOT PITCH 7) EAST TOILET ROOM LESS THAN ? FINISHED AND 15" ARE REQUIRED FROM TOILET FLANGE CENTER LINE TO FINISHED WALLS 8) TOP STAIR THREAD HAS LESS THAN 10" WIDTH FROM BULL NOSE TO BULL NOSE |
|
| 02/16/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO TEST ON GAS LINE 2) 2SD2 NOT COMPLIED WITH IN LAUNDRY ROOM 3) BLOWN FIRE BLOCK AT ENTRY 4) PROVIDE 1/4" PER FOOT DROP AT DRAINS 5) LEAK AT KITCHEN WATER LINES 6) STOPPED INSPECTION |
|
| 02/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL PENETRATIONS FROM 1ST TO 2ND FLOOR 2) GAS TEST AT ZERO 3) FIRE BLOCK MECH CHASE 4) NO T-TOPS INSTALLED 5) BLOCK MECH IN MASTER 6) SK2 REPAIR IS FOR LOT 32, PROVIDE APPROVED REPAIR FOR THIS HOUSE 7) NOTE: LOT 32 APPROVAL WAS 8/3/04 |
|
| 02/11/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MECHANICAL NOT COMPLETE 2) MISSING T-TOPS 3) PENETRATIONS NOT FIRE BLOCKED 4) GAS LINE NOT COMPLETE 5) STOPPED INSPECTION |
|
| 02/09/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LADDER BLOCKS MISSING AT LAUNDRY 2) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR AND INTO ATTIC SPACE 3) 2SD2 NOT COMPLIED WITH 4) GAS TEST AT 0 PSI 5) NAIL PROTECT VENT AT POWDER ROOM 6) STOPPED INSPECTION |