Permit: T04CM03856

Parcel: 140324150

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM03856

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/10/2004 FRAMING Approved IVRS - Inspection :*
12/08/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL BLOCK BETWEEN HI-LOW COMBUSTION OPENINGS IN GARAGE
2) TIGHTEN ANCHOR BOLTS ? WALLS
3) REPAIR TOP PLATE AT DRYER VENT
4) WIRE MUST BE INSULATED TO INTERIOR OF BOX IN HALLWAY BY GARAGE
5) GROUND EXTERIOR METAL BOXES
6) NAIL PROTECT VENT STACK MASTER BEDROOM WATER CLOSET
7) NAIL PROTECT TUB VENTING SECOND TUB
8) FIRE BLOCK KITCHEN EXHAUST
9) COMPLETE ARCH WAYS TO KITCHEN AND HALL WAY
10) SHIM ALL BEARING HEADERS
11) WATER TESTS OK
12/06/2004 FRAMING Not ready for Inspection IVRS - Inspection :*