Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T04CM03841
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :*1) PLUMBING FINAL OK. 2) OK FOR C OF O PENDING ANY OTHER INSPECTION. | |
| 12/10/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*1)WHERE IS ISOLATION VALVE AT ANSUL? LOOP 2)NOT NO GRATES ON FLOOR SINK. 3)CONTRACTOR WILL REMOVE ALL MACHINE SCREWS FOR C.P. CLEAN-OUT COVERS, REMOVE RAISED SQ HEAD PLUGS AND INSTALL COUNTER SUNK TAPPED CLEAN OUT PLUGS...THEN CUT THE SCREW TO LENGTH AND LEAVE COVER AND SCREW NEXT TO CLEAN OUT. 4)GAS NOT INSTALLED PER PLAN 5)CERTIFICATIONS ON BACKFLOW DEVICES NOT AVAILABLE 6)HOOK-UP ALL EQUIPMENT MAKE ALL CONNECTIONS. INSTALL ALL VALVES 7)CALL IN ALL REQUIRED INSPECTIONS | |
| 12/08/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/1)PLAN APPROVED IN ERROR. P-5 PLUMBING FIXTURE SCHEDULE BACK FLOW PREVENTER WATTS 9BD NOT APPROVED DEVICE. INSTALL APPROVED, TESTABLE ASSEMBLY 2)OK TO COVER INTERCEPTOR. CONTRACTOR TO INFILL CORE HOLE FOR VENT 3)ALL INDIRECT WASTE PIPING SUBJECT TO 94UPC 4)GAS PRESSURE TEST OK - OK TO INSTALL ANSAL? VALVE | |
| 12/07/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/1)MAKE ALL CONNECTIONS, HOOK UP ALL EQUIPMENT 2)ALL INDIRECT WASTE PIPING IS GOVERNED BY 94 UPC 3)HAVE PLUMBER | |
| 12/06/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) NOTE: CLEANOUT PLUGS UNDER A CP COVER NEED TO BE COUNTER ? TAPED PLUGS WITH MACHINE SCREW. WOOD SCREWS OR SHEETROCK SCREWS ON A RAISED SQUARE HEAD TEST PLUG-NOT ACCEPTED |