Permit: T04CM03840

Parcel: 137053350


Addresses:

843 W WYOMING ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/01/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/24/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :REMOVE ALL BIRD BOARDS FOR INSPECTION OF H25 CLIPS
ROOFING TACKS NOT ALLOWED TO INSTALL H2.5 CLIPS - YOU MUST USE #8 TECO NAILS OR 16 D NAILS REPLACE ALL ROOFING NAILS OR ADD H 2.5 CLIPS WITH PROPER NAILS
O.S.B. MUST BE SUPPORTED ON ENDS AND EDGES. INSTALL FACIA AND RAKE RAFTERS. NAIL ENDS AND ALL SUPPORTED EDGES AT 6" ON CENTER MAXIMUM SPACING.