Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T04CM03838
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/16/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :*10 PSI PRESSURE TEST ON INTERIOR GAS PIPING OK CALL FOR GAS FINAL TO GET APPROVAL FOR METER CONNECTION. ABOVE CEILING OK TO COVER |
|
11/07/2005 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 1) 70 PSI TEST FROM METER TO 1 1/2 STUBBED INTO WATER HEATER ROOM OVERHEAD, UP TO ROOF TO (3) AHU'S WITH (1) 2" DROP DOWN INTO KITCHEN CAPPED AT WALL AND (1) 1 1/4" DROP DOWN INTO KITCHEN CAPPED AT WALL. 1 1/4 KITCHEN PIPE TO BE SECURED. 1 1/4" PIPING TO AHU #3 TO HAVE SHUT OFF VALVE WITHIN 3' OF APPLIANCE AND CAP ON DRIP LEG SHALL NOT CONTACT ROOF |
|
11/03/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
10/26/2005 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :*3" MAIN GAS FROM METER TO STUB UP AT ROOF INCLUDING 1 1/2 T-O-L FRO WATER HEATERS OK | |
10/24/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* |