Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/09/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* MODULAR BUILDINGS INSTALLED |
|
| 09/09/2005 | BUILDING - FINAL | Partial Approval | OK FOR TEMP C OF O | |
| 09/09/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) STRUCTURAL, EGRESS AND CHAPT. II REQUIREMENTS COMPLETE FOR MAIN BLDG 2) PERMIT MAY NOT BE FINALED UNTIL MODULAR BLDGS REMOVED FROM PLANS OR INSTALLED 3) OK TCO FOR BLDG 1 PHASE 1 |
|
| 09/08/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 09/07/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) H.C. PARKING SPACES MAY NOT SLOPE MORE THAN 2% IN ANY DIRECTION 2) 9-2-05 SEE ITEM #3 3) #7 ABOVE TO BE BROUGHT DM? ATTEN 4) I NEED ELEC FINAL AND C OF O FINALS |
|
| 09/02/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) REQUIRED 7' TO BOTTOM OF H.C. PARKING SIGNS 2) EARTH MUST SLOPE AWAY FROM BLD ON N. SIDE 3) BICYCLE PARKING FACILITIES 4) SIGN AT MAIN ENTRY "POOL TO REMAIN UNLOCKED..." 5) SMOOTH OUT RAMP LEADING? EDGE TO STAGE 6) H.C. STALLS IN ACCESSIBLE RESTROOMS REQUIRE DOOR TO SWING IN 7) WOMENS RESTROOM ENTRANCE DOOR REQUIRES 18" CLEAR ON LATCH SIDE YOU HAVE 14" ANSI 117.1 (AS REF BY IBC CBYLL?) SECTION 404.2.3 YOU NEED 18" SIDE CLEAR ON PULL APPROACH 8) PROVIDE FINAL FROM ALL OTHER TRADE INSPECTORS 9) FINISH ALL WORK |