Permit: T04CM03803

Parcel: 117062930


Addresses:

428 E 9TH ST


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM03803

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
10/01/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/29/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PLUMBER TAPE NOT ALLOWED TO SUPPORT WASTE LINE 2) PVC TRANSITION TO COPPER PVC SHALL BE MALE ADAPTOR 3) SHIM EXISTING GIRDERS WHERE NOTCHED
09/28/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) LEAK ON 1/2" 90 DEGREE ABOVE BEDROOM #2 2) PROVIDE WATER TEST ON DWV SYSTEM
09/24/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
09/20/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*/ 1) SANITARY 'T' FITTINGS CANNOT BE USED IN THE FLAT HORIZONTAL DRAIN MUST USE DIRECTIONAL FITTINGS 2) SHOWER MUST BE 2" DRAIN AND TRAP 3) SHOWER NOT VENTED 4) VENT 90 FITTINGS CANNOT BE USED AT THE BOTTOM OF A VERTICAL DRAIN 5) HOUSE IS NOT PLUMBED PER PLAN OR CODE 6) NO WATER TEST ON DWV 7) STOPPED INSPECTION
09/17/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) CANNOT REDUCE DRAIN PIPE SIZE. WASHERS 2" TO 1 1/2"; BATH OUTSIDE. LINE 4" TO 3" TO 4"