Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/04/2005 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 10/11/2004 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/1)WE HAVE CONDUCTOR OUTERFILL? IN CEIL? BOXES. OK WALLS-CHECK ON FINAL | |
| 10/07/2004 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :MET ELECTRICIAN AND WENT OVER JOB | |
| 10/01/2004 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :PROTECT CABLES AT STUDS SUPPORT CABLES AS PER CODE PLESE USE APPROVED CONNECTOR TO SECURE CABLES TO BOX & EXHAUST FANS STRAPING IS TO BE EFFECTIVE - USE APPROVED METHODS TIGHTEN LOOSE FITTINGS USE APPROVED & LISTED JUNCTION BOX BOXES TO EXTEND OUT OF WALL KITCHEN CIRCUITS NOT TO SUPPLY ANY OTHER OUTLETS |