Permit: T04CM03797

Parcel: 136287880


Addresses:

7447 E POINCIANA PL


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM03797

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/16/2005 FRAMING Approved IVRS - Inspection :*
03/14/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/13/2004 FRAMING Partial Approval IVRS - Inspection :*
1) PARTIAL FOR FIRE RATING PROPERTY LINE ENCROACHMENT
12/10/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRE PROTECT ALL OVERHANGS WITHIN 3' OF PROPERTY LINE
2) NAIL PROTECT ROMEX WIRING THROUGHOUT HOME WHERE NEEDED
3) NO WATER IN DWV WATER TEST
4) WATER IN ALL PEX LINE APPROVED
12/07/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NORTH BED WINDOW SILL ABOVE 44"
12/02/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) TIGHTEN ANCHOR BOLTS
2) SHIM HEADERS WHERE NEEDED
3) BANG PLATE ELECTRIC WHERE NEEDED
4) FHA STRAP STUDS/PLATES WHERE NEEDED AT OVER BORES
5) BLOCK DUCT BOOTS WHERE NEEDED
6) STUD SHOE AT KITCHEN ABS
11/29/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
11/24/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
11/22/2004 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*/ 1) MAKE UP ALL ELECTRIC GROUNDS AND SECURE WITH A MECHANICAL FASTENER
2) GROUND ALL METAL ELECTRIC BOXES
3) NAIL PROTECT PLUMBING WITHIN 1 1/2" OF STUD SURFACE
4) INSTALL FHA STRAPS ON DBL TOP PLATE CUTS
5) NAIL PROTECT DRYER VENT
6) NO DWV WATER TEST
7) BLOCK DUCT BOOTS 3 SIDES
8) OVER BOARDED BEARING STUDS AT KITCHEN DIRTY ARM. ADD STUD SHOES OR DBL STUDS
9) BEDROOM EGRESS SILLS TO HIGH EXCEEDS 44"
10) SHOWER SILL REQUIRES TREATED LUMBER
4) NAIL