Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM03786
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/08/2004 | FRAMING | Approved | IVRS - Inspection :* | |
10/07/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) NO PLANS/PERMIT ON SITE | |
10/06/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
10/05/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) NEED DWV TEST 2) CHECK TRUSS DRAWINGS FOR CORRECT, TRUSS FOR SHEAR TRANSFER GARAGE TO HOUSE WALL 3) BANG PLATE EXT. SIDE H20 SERVICE 4) LATH NOT DONE 5) BACKING AT TOP OF DRYWALL, REFRIDGERATOR ALCOVE 6) CHECK BEARING PTS (4) AU1, AU1A 7) PATCH HOLE AT TUB BLK OUT WEST BATH 8) BANG PLATE ROMEX TOP/PL LEFT OF FRONT DOOR 9) FULL BEARING 3 PT TRUSS LIVING ROOM 10) FLEX CONDUIT REAR PORCH LIGHT SECURE INSIDE WALL 12) BROKEN PLATE EAST BATH, DBL LAV 13) LOOSE B/PLATE EAST BATH BEHIND TOILET 4) CONTROL WIRE CUT LAUNDRY ROOM 15) GAS/H20-OK |