Permit: T04CM03774

Parcel: 138133590


Addresses:

461 W HAMMERHEAD WY

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/20/2005 FRAMING Approved IVRS - Inspection :*
01/19/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE
2) 49/AD3 AND 50/AD3 NOT COMPLIED WITH OSB NOT ALLOWED
3) BEARING WALL NOT ANCHORED OR CLIPPED UNDER STAIR
4) ELECTRIC OUTLET MISSING AT USABLE WALL SPACE SECOND FLOOR
5) WIRES CHAFFING ON TRUSS GANG NAILS
6) 2ND FLOOR BOTTOM PLATES NOT NAILED PER 1/SD2
7) STOPPED INSPECTION, TOO MANY ITEMS
01/18/2005 FRAMING Not ready for Inspection IVRS - Inspection :*