Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/17/2005 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection 7/sd2 not complied with at laundry shearwall OSB shear not nailed at laundry Floor truss overspan at west wall maximum allowed 24" span 27 1/2" Seal 2nd floor penetrations Firestop chase south wall between 2030 windows Firestop east wall of stairwell 2nd floor Water heater vent has greater than 3/4 horizontal to vertical run ratio only 4' rise maximum run 3 ft |
|
| 02/16/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO TEST ON DWV'S 2) SEAL PENETRATIONS FROM 1ST TO 2ND FLOOR 3) REPAIR SHEAR AT WATER HEATER AREA 4) OVERSPAN AT KITCHEN WALL 5) PROVIDE 16 GA. STRAP WITH 16D NAILS DBL TOP PLATE AT KITCHEN 6) NAIL PROTECT PLUMBING IN KITCHEN 7) STOPPED INSPECTION |
|
| 02/15/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) PLUMBING NOT COMPLETE 2) NO DWV OR POTABLE WATER TEST 3) INSTALL 2 FHA STRAPS AT DBL TOP PLATE CUT FOR 3" DWV 6-16D NAILS EACH SIDE 4) NO GAS PRESSURE TEST 5) STOPPED INSPECTION NOT COMPLETE ENOUGH TO INSPECT |