Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM03750
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/18/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/1)CONDENSATE WASTE MAY NOT TERMINATE AT A SINK TAILPIECE. 2)WHATEVER METHOD IS USED TO PIPE UNIT, MAKE SURE IT IS ON THE APPROVED PLAN | |
10/05/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) SEE NOTE FROM 09/23/04 2) REVIEW TABLE 3-194 UPC HANGERS & SUPPORTS 3) REVIEW IS -5 94 UPC 314.2 SUPPORT. REQUIREMENTS FOR ABS ( ALL SIZES) HANGERS AT THE END OF BRANCHES. CHANGES OF DIRECTION. CHANGES OF ELEVATION. AND THEN -NO MORE THAN FOUR FEET BETWEEN HANGERS. | |
09/23/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ROOM #116 OK TO COVER WALLS. DON'T FORGET-CHANGE OF DIRECTION, ELEVATON, AND END OF BRANCHES REQUIRE SUPPORT. |