Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/30/2004 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection :* 1) RM # 126 KITCHEN ABS UNDER SLAB OK THIS COMPLETES UNDERGROUND |
| 09/21/2004 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection :* TOILET # 140 & KITCHEN # 116 OK TO COVER UNDERGROUND ONLY |
| 09/20/2004 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection :*/1)TEST WYE? INSTALLED AGAINST FLOW 2)HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE WYE? BRANCH OR EQUAL 3)VERTICAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 4)HORIZONTAL VENTING? BELOW FLOOD LEVEL NOT ALLOWED (DRAINAGE FITTINGS IF CIRCUMSTANCES ALLOW) |