Permit: T04CM03747

Parcel: 136404900

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM03747

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/23/2005 FRAMING Approved IVRS - Inspection :*
03/21/2005 FRAMING Partial Approval IVRS - Inspection :*
1) ATTACH BLOCKING REGISTER S.W. BEDROOM
2) FIRE BLOCK UNDER TUBS
3) NAIL NR 132 HANGER N.W. BEDROOM
4) ADD SUPPORT UNDER GIRDER TRUSS AT 2ND FLOOR FURNACE ROOM
5) NAIL OFF STRAPS 1ST TO 2ND FLOOR NORTH SIDE OF HOUSE
6) NAIL STOPS TOP PLATE GARAGE
7) CHECK NAIL STRAPS THRU-OUT HOUSE
8) COVER MISSING RECESSED LITE
9) NAIL STOP AT TUB
10) PROPERLY SUPPORT ALL 2ND FLOOR ABS
11) CHECK NAIL STOPS THRU-OUT HOUSE
12) SECURE SUPPLY BOX IN BONUS ROOM
13) NEED 1" CLEARANCE TO FURNACE B-VENT
14) REMOVE BLOCK AT TUB (2ND FLOOR) TO GET 1" CLEARANCE TO B-VENT