Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM03735
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/21/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
03/21/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) CORRECTIONS MADE OK OK TO COVER | |
03/17/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* PARTIAL APPROVAL WATER TEST WASTE & VENT UNDERGROUND ONLY FOR ( 3) S-2 ( 1) S-4 FROM POINT OF CONNECTION TO 4" BUILDING DRAIN FOR INITIAL AT EXISTING ( ONLY) 1) WILL NEED TO SEE CORRECT TRANSITION COUPLING FOR 4" ABS TO 4" C.I TO EXISTING BUILDING DRAIN. | |
03/15/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) GANZ PLUMBING IS CONTRACTOR ON JOBSITE. 2) PIPE TO BE INSTALLED IN PRACTICAL ALIGNMENT 3) CLEANOUTS REQUIRED IN DRAINAGE OVER 135 DEGREEES. 4) OK TO COVER BATHROOMS AND TRUNK LINE- ALSO FOR 3 SINK | |
03/14/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
03/11/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLEASE PROVIDE LICENSE FOR PLUMBING CONTRACTOR AS REQUIRED BY LAW. |
|
03/10/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STILL NOT READY FOR INSPECTION 2) BACK PITCHED PIPE TO BE CORRECTED |
|
02/16/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOT INSTALLED PER PLAN. NO REDLINES ON SITE. TRENCH TOO WET FOR INSPECTION. BRIDGING NOT PERMITTED-MUST BE LAID ON FIRM BED. BRANCH PIPING OVER FIVE FEET FROM MAIN REQUIES FULL SIZE CLEAN-OUT. HORIZONTAL VENTING BELOW FLOOD RIM RESTRICTED TO STRUCTURAL CONDITIONS |