Permit: T04CM03732

Parcel: 12315104A


Addresses:

744 E ADAMS ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM03732

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/10/2005 FRAMING Approved IVRS - Inspection :*
08/09/2005 FRAMING Partial Approval IVRS - Inspection :*
08/08/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) UNABLE TO ENTER TO INSPECT
2) FRONT GATE LOCKED
06/24/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) STUCCO LATH NOT COMPLETE-MUST BE COMPLETE BEFORE INTERMEDIATE INSPECTION CAN BE APPROVED
2) MANY BEARING STUDS NOTCHED MORE THAN 25 PERCENT-REPLACE
3) DBL TOP PLATES NOTCHED AT GLUE-LAM BEAMS. PROVIDE FHA STRAPS
4) JIM CAP-TEST CAP CANNOT BE ENCLOSED IN WALL CAVITY-MUST BE PERMANENT CAP AT KITCHEN
5) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE
6) A/C REQUIRES 3/4" CONDENSATE
7) CONDENSATE OVERFLOW CANNOT BE ENCLOSED IN CEILING-PROVIDE INSTALLATION MANUAL FOR A/C
8) FIRESTOP SECOND FLOOR INCLOSED AREAS FLOOR AND CEILING
9) CUT OFF TJI BY STAIR REQUIRES SUPPORT
10) STAIR RISERS HAVE MORE THAN 3/8" DIFFERENCE IN RISE
11) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE
12) STOPPED INSPECTION-TO MANY ITEMS
03/01/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE AND RECALL CLIP AND SHEATHING/ROOF NAILING INSPECTIONS