Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/03/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/02/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEE LAST INSPECTION 2) CABLES NOT TENSIONED |
|
| 11/30/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) POST TENSION CABLES NOT TENSIONED 2) CLIPS AT ENTRY MISSING NAILS 3) WIND BRACING MISSING NAILS 4) PROVIDE BACKING FOR LATH AT PATIO 5) STRAP PATIO BEAM 6) COMPLY WITH DETAIL 7SD3 7) CLIPS MISSING NAILS AND CHECK FOR OVERSPANS 8) PROVIDE APPROVED REPAIR FOR TRUSS A-7 9) HJ8 HANGER MISSING NAILS 10) CHECK ENTIRE ROOF FOR NAILING AND SHEATHING MUST SPAN 2 BARS 11) COMPLY WITH 6ASD3 |