Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/18/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/16/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PROVIDE STUD SHOE OR REPLACE 2 X 6 STUD AT MASTER BATH 2) DWV'S OK, REST OF HOUSE OK |
|
| 02/15/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 2" DRAIN NOT ALLOWED IN LAV MASTER BATH CHANGE AND RETEST |
|
| 02/09/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MECH CHASE NOT FIRE BLOCKED 2) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT B-VENT 3) PROVIDE STUD SHOE AT 2 X 6 BEARING STUD AT MASTER BATH 4) FLEX IN LIVING ROOM OBSTRUCTED |
|
| 02/07/2005 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio |
|
| 02/03/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 02/02/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXHAUST FAN IN LAUNDRY ON FLOOR 2) PROVIDE 12" CLEARANCE FROM CAN LIGHTS TO WATER LINES 3) ROMEX HANGING FROM CEILING AT SLIDER AREA 4) ADD STUD SHOE TO 2 X 6 STUDS AT MASTER BATH 5) FLEX DUCT FULL OF WATER, REPLACE IN MASTER BATH 6) 2" DIRTY ARM NOT ALLOOWED FOR LAV 7) NO TEST ON DWV'S UPSTAIRS |
|
| 01/28/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1 NAIL PROTECT WATER LINE AT POWDER ROOM 2 RIBBON NOT NAILED AT ENTRY 3 FIRE BLOCK MECH CHASE 4 PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT B-VENT 5 NO TEST ON DWV UPSTAIS 6 STOPPED INSP NOTHING DONE SINCE LAST INSP |
|
| 01/26/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PATIO FLASHING NOT INSTALLED 2) LATH NOT COMPLETED AT PATIO 3) BLOCKING PANELS MISSING 4) STRAP HEADERS 5) 3" DRAIN OUT OF WALL 6) EXHAUST FAN IN LAUNDRY MISSING 7) NO TEST ON DWV'S 8) COMPLY WITH STAIR DETAILS 9) STOPPED INSPECTION |