Date Description Inspector Results Comments
09/20/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/ 1) CORRECTIONS MADE 2) GAS CARD AT METER
09/15/2004 PLUMBING - FINAL Denied IVRS - Inspection :
14 PSI AIR TEST ON NOW PIPING FROM NEW METER LOCATION TO WATER HEATER ( ONLY) OK
1) PROVIDE BONDING OF BUILDING GAS PIPING. 2) WATER HEATER T& P DRAIN TO BE SECURED PROPELY AND TERMINATE WITH 90 DEGREE DOWN. 3) PROVIDE APPROVED COUPLINGS AT TRANSITION FROM ABS TO CAST IRON. 4) PROVIDE APPROVED TRANSITION FROM GALV PIPE TO COPPER. 5) PROVIDE APPROVED FITING FOR VENT FOR WASHING MACHINE BOX. 6) PROVIDE SUPPORTS AT 4" INTERVALS WITH 2-HOLE STRAPS FOR SECURING ABS DRAIN. 7) REMOVE UNION THAT WILL BE IN UNACCESSABLE LOCATION. 8) PROVIDE PERM CAP AT 1 1/2 GALV STUB AT OLD WASHER LOCATION. 9) CALL IN BOTH INSPECTION # TO4CM03701 AND T04CM03986 WITH ALL PLUMBING INSPECITON NUMBERS LISTED ON BOTH CARDS.
09/13/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
08/31/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/30/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*