Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T04CM03692
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/24/2004 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
09/22/2004 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) LOOSE RUBBLE IN FOOTINGS 2) IMPROPER CLEARANCES AT FORMS TO BOTH CABLE AND REBAR 3) 1"MAXIMUM EXPOSED STRAND AT LIVE ENDS 4) MAKE SURE TENDON PROFILES ARE FLAT THROUGH SLAB (EXCEPT AT TURNDOWNS) |
|
09/21/2004 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection :DENIED. 1) MOVE EARTH AWAY FROM FORMS 3' FOR PROPER TENDAN PROFILE @ STRESSING END. 2) MAINTAIN 3/4" CLEAR TO STRAND @ DEAD ENDS. 3) MAKE SURE SUB GRADE IS PROPER ELEVATION AND FLAT NECESSARY WHEN CHAIRS ARE ON GRADE AND TENDAN PROFILE IS FLAT. |